Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Carousel with three slides shown at a time. Use the Previous and Next buttons to navigate three slides at a time, or the slide dot buttons at the end to jump three slides at a time. Microscope 4k Camera

Improvement of the signal to noise ratio for fluorescent imaging in microfluidic chips | Scientific Reports

Anish Priyadarshi, Firehun Tsige Dullo, … Ganapathy Senthil Murugan

Yanyu Xiong, Qinglan Huang, … Brian T. Cunningham

Yuchao Li, Xiaoshuai Liu & Baojun Li

Øystein Ivar Helle, Firehun Tsige Dullo, ... Balpreet Singh Ahluwalia

Zheshun Xiong, Fuu-Jiun Hwang, … Guangyu Xu

Tal Gilboa, Adam Zrehen, … Amit Meller

Qitong Li, Jorik van de Groep, … Mark L. Brongersma

Tianlong Zhang, Misuzu Namoto, … Yoichiroh Hosokawa

Larissa Kohler, Matthias Mader, … David Hunger

Scientific Reports volume  12, Article number: 18911 (2022 ) Cite this article

Microfluidics systems can be fabricated in various ways using original silicon glass systems, with easy Si processing and surface modifications for subsequent applications such as cell seeding and their study. Fluorescent imaging of cells became a standard technique for the investigation of cell behavior. Unfortunately, high sensitivity fluorescent imaging, e.g., using total internal reflection fluorescence (TIRF) microscopy, is problematic in these microfluidic systems because the uneven surfaces of the silicon channels’ bottoms affect light penetration through the optical filters. In this work, we study the nature of the phenomenon, finding that the problem can be rectified by using a silicon-on-insulator (SOI) substrate, defining the channel depth by the thickness of the top Si layer, and halting the etching at the buried SiO2 layer. Then the fluorescent background signal drops by = 5 times, corresponding to the limit of detection drop from = 0.05 mM to = 50 nM of fluorescein. We demonstrate the importance of a flat surface using TIRF-based single-molecule detection, improving the signal to a noise ratio more than 18 times compared to a conventional Si wafer. Overall, using very high-quality SOI substrates pays off, as it improves the fluorescence image quality due to the increase in signal-to-noise ratio. Concerning the cost of microfluidic device fabrication—design, mask fabrication, wafer processing, and device testing—the initial SOI wafer cost is marginal, and using it improves the system performance.

With the advent of micromachining, microfluidics technology also became a common technique, starting with chemical and biochemical reactors, sample sorting, mixing, and biosensing. There are several techniques for sensing: electrochemical methods such as voltammetry, galvanometry1, or impedance spectroscopy2, and electrical methods such as impedance measurement3 and mass detection using external mass spectroscopy4 or internally either surface acoustic waves5 or quartz crystal microbalance6. They all require the implementation of electrodes inside the microfluidic channels. Of course, it is possible, but it makes the device fabrication process more complicated—a problem for disposable chips.

In principle, optical methods have advantages compared to electrical. The optics will never contact the analyte, so there is no need for disposal to eliminate sample-to-sample cross-contamination. Colorimetry7 and turbidity8 measurements are simple methods but their limit of detection (LOD) rather high preventing them to be commonly used. The methods based on plasmon generations, such as surface plasmon resonance (known as SPR)9 or localized surface plasmon resonance (known as LSPR)10, are more complex. The first requires a gold-coated substrate placed on a rotating prism with a laser detecting the minimal incident angle; the second uses an easier setup but requires determining the spectrum by use of a spectrum analyzer11 reflected from the nanostructured surface. Unfortunately, these methods all have one feature in common, which is relatively high noise that leads to the insufficient (LOD) for numerous applications.

Nevertheless, there are a few optical techniques commonly used with a sufficiently low level of LOD such as electrochemiluminescence (ECL)12 and fluorescence13. The ECL method requires an electric field-triggered redox reaction, either with an external power supply concerning the electrodes14 or by using free-floating metal platelets large enough for the applied external electric field to reach at least 1 V voltage drop in the vicinity of the platelets15. These methods have one great advantage of having almost no light in the background, as there is no external light required. Fluorescence-utilizing methods are based on the excitement by illumination, using lower wavelengths to excite electrons from an orbit and detecting relaxation to a lower energy state, exhibiting light generated with a longer wavelength than the one that was used for excitation. The exciting light historically originated using either Ar laser or Hg and Xe lamps. All those light sources are multispectral and the user has to select correct wavelengths, such as 488 nm from the Ar laser source or one of ultraviolet (UV) i-line (365 nm), h-line (405 nm), or g-line (436 nm), or longer wavelengths of 488 nm, 546 nm or 579 nm from Hg and Xe lamps, using appropriate optical filters to block the other wavelengths.

Typical materials are fluorescein16 and rhodamine 6G17, which excite with the highest efficiency excitement wavelength of = 490 nm (pH-dependent) and 570 nm (solvent-dependent), and the highest power of emission wavelength of 515 nm and from 580 to 590 nm, respectively. Apart from the basic fluorophores, there are a large number of others for various purposes such as chemical and biochemical analysis monitoring, DNA detection using real-time polymerase chain reaction (qPCR)18, digital polymerase chain reaction (dPCR)19, enzyme-linked immunosorbent assay (ELISA)20 and cell imaging21. Here, fluorescence plays an indispensable role; researchers can greatly enhance the cell contrast as well as the parts, using a live-dead assay to identify ratios between live and dead cells22.

There is a phenomenon preventing high-resolution microscopy inside microfluidic devices such as autofluorescence of plastic materials used for microfluidic chip fabrication. We noticed a similar problem in our chips made of silicon capped with glass with an anodic bonding; clearly, no materials were exhibiting significant autofluorescence, if any. The high-end filters are based on interference by multilayer thin films; thus, they are sensitive to light incidence angles as it is shown in Semrock’s website in using MyLightTool application available there23. In this work, we performed a detailed study of microfluidics to discuss the origin of the background noise and the method of suppressing it by two orders of magnitude allowing more sensitive fluorescence measurement as well as he total internal reflection microscopy to be used with its maximum resolution (TIRF)22.

The typical fluorescent optical system consists of: a light source; an excitation filter (XF) to keep unwanted components from exciting light and possibly interfering with the results; a dichroic mirror (DM) to reflect filtered excitation light on the specimen; and an emission filter (MF) to block filtered exciting light, allowing only the emitted light to pass to the optical detector, which can be a photodiode, photomultiplier tube (PMT), or a suitable camera.

Here we used high-end optical filters, ET series model 49,002 (Chroma Technology Corp., Bellows Falls, VT, USA) intended for the FITC type of fluorescence25. The filters have excellent parameters, with the nearly 100% of transmission in the desired band from 450 to 488 nm and from 500 to 548 nm, with an excellent raise and falling edge of 1.478 and − 1.563 nm dec−1 and 1.524 and − 0.899 nm dec−1 for XM and MF, respectively (Fig. 1A). Their excellent properties are achieved by the interference effect, using multiplayer coatings having up to 150 layers of ET series. Unfortunately, that is only acceptable for light perpendicular to the filter surface, i.e., for an incident angle close to 0°. Once this angle significantly deviates from 0°, the properties of the filters change due to the different lengths of the light optical path26. Typically, that is not a big problem for transmission light-based fluorescence measurement. However, reflection light-based observation and imaging is sensitive to light scattering due to dispersion at surface topography, such as in the precipitated crystals of buffer solution in the digital polymerase chain reaction chip (Fig. 1B). Also surface roughness affecting the fluorescent imaging is known from previous fluorescent spectroscopy measurement27 including total reflection fluorescence28.

(A) Fluorescein isothiocyanate (FITC) filter set transmission showing properties of the excitation filter (blue), dichroic mirror (red), and emission filter (green). Both excitation and emission filters have a light incident angle of 0° while the dichroic mirror is 45°. (B) A fluorescent image of a digital polymerase chain reaction (dPCR) chip from Stilla24 using an FITC filter set. The droplets contained precipitated salts from the buffer exhibiting false fluorescent signal.

Recently, the precise model of a thin-film interference filter has been conducted showing its property’s sensitivity to the angle of incident light29. It is well known effect which can be simulated by a specialized optical software as well as using online tools such as Semrock’s MyLightTool23. Unfortunately, Chroma Optical does not offer these details of the sputtered layers in public domain thus we had to measure it.

We used a light-emitting diode (LED) with a principal wavelength of 475 nm as a light source. This light was filtered by XM to block light with a wavelength longer than 490 nm, and after passing through FM mounted on a rotating platform, the transmitted light was detected either by a spectral analyzer or by a PMT through an optical fiber system. In principle, there should be no significant power of light passing through the system when the incident light angle at both filters is 0°. We measured this light spectrum penetrating through the system as a function of the incident angle at the FM filter (Fig. 2). The optical spectrum was measured directly using the LED DC power with 20 mA of electrical current. We shielded the system from the ambient to avoid unwanted interference.

(A) Diagram of the light measurement through the rotated filter showing LED with a principal wavelength of 475 nm (LED 475 nm) connected to the excitation filter (blue) perpendicular to the light via optical fiber and attenuator (AT), emission filter (green) on a rotating platform, and either a photomultiplier tube (PMT) as light detector (shown here) or spectrum analyzer (not shown here). (B) Schematically showing the green filter rotation and its influence on (C) measured detected power on the PMT and (D–F) detected spectra for four different angles of the emission filter position.

The PMT setup was different. We powered the LED using = 10 mA of electrical current and set its modulated power at a frequency of 1.012 kHz using a signal generator. The PMT was set with minimal gain, having 0.5 V voltage at the gain control input. The PMT output signal was demodulated by a lock-in amplifier with sensitivity set to 1 V scale−1, with a time constant set to 100 ms. As we used a lock-in amplification system, optical path shielding from ambient light was not essential.

Initially, the light source, filters, and detector were adjusted to be collinear. We then rotated the green filter to reach the maximal amplitude value of the PMT output and recorded the response as well as the angle value of = 9.78 V and = 318.5°, respectively (Fig. 2A). The amplitude value was decreased, and the angle was decreased in steps of 0.1° and recorded until it plateaued. The same measurement was done on the other rotation side, starting with a similar amplitude of = 9.84 V according to the angle of = 356.2°. We then shifted the center of the curve to zero by calculating the offset of the measurement using a linear curve fitting in a descending stage (Fig. 2B). The spectrum of the changing rotation angles was also measured (Fig. 2C–G). We found that the filter maintains its properties in a range of incident angles from = − 15 to = 15°. Once the absolute value of an incident angle is greater than = 15°, light that is normally blocked begins to penetrate through the filter, resulting in overall power increases of transmitted light.

The thin-film interference filter is sensitivity to the angle of incident light resulting in the rough surface more fluorescence noise. We provide the solution by chip fabrication based on SOI wafer and compared the fluorescence signal from the same structure on different substrates.

We designed our chips (Fig. 3A) using Nanolithography Toolbox30, having 16 chambers with tangential tube connections31, each with an area of = 15 mm2, a depth of = 100 µm, and a volume of = 1.5 nL, and visualized a single chamber using computer-aided software (Fig. 3B). We used our conventional microfabrication technique for microfluidic chips, consisting of patterned Si substrate using two lithography steps and a non-patterned glass cover anodically bonded to the Si substrate32. We conducted both lithography steps on a flat substrate giving us no additional challenges, such as performing lithography on a substrate with significant topography changes. Then we used the Bosch process with deep reactive ion etching (DRIE) based on a combination of SF6 etching and C4F8 polymer deposition. This is a well-known process with an excellent etch rate of a few µm min−133. The etched Si wafer was then capped using anodic bonding, an easy task since there was no pattern on the glass substrate, meaning no strict alignment rules had to be followed.

Description of the microfabrication processes based on different surface. (A) Layout of the chip with individual chamber for fluorescence measurement and (B) its visualization using computer-aided software. (C) Chip fabricated using conventional Si and (D) SOI substrate.

The fabrication was first conducted using conventional Si wafers with a diameter of = 100 mm (Fig. 3C-a1). The wafers were oxidized in a furnace using a wet O2 environment to grow a SiO2 layer with a target thickness of 100 nm (Fig. 3C-b1). Then the wafers were spin-coated with a photoresist (Fig. 3C-c1), and the first lithography was performed defining the chambers and the channels. After the photoresist development, the SiO2 layer was etched using a reactive ion etching of a CHF3/O2 gas mixture (Fig. 3C-d1). The photoresist was removed, the wafers were cleaned, and we spin-coated a second photoresist layer—this time with a thickness between 10 and 12 µm (Fig. 3C-e1). After exposure and development, the wafers were etched by DRIE through the entire Si substrate to form the access holes for fluid inlets and outlets (Fig. 3C-f1). Then the photoresist was removed, and a second DRIE step was conducted for the 100 µm depth required for the chamber. This time, the original patterned SiO2 served as a mask (Fig. 3C-g1). The masking SiO2 layer was removed by wet etching using HF/NH4F with concentrations of 49% and 40%, and the ratio between them of 1:6. The last fabrication step was thermal oxidation of the wafers at a set temperature of 900 °C to grow a 5 nm layer of thermal SiO2 to define the chamber surface properties. Finally, the Si wafers were anodically bonded (Fig. 3C-h1) with Corning 7440 glass substrate with a diameter of = 100 mm and a thickness of = 170 µm (Fig. 3C), as the TIRF microscope objective lens is optimized for this glass thickness.

Once the wafers were diced into individual chips (Fig. 3C), they were coated with FAS-17 fluorosilane using a combination of wet incubation and chemical vapor deposition at a lower pressure at an elevated temperature, leading to self-assembly monolayers with excellent properties such as contact angles higher than 105°32,34. We also performed identical fabrication using an SOI substrate diameter of 100 mm, a buried SiO2 thickness of 100 nm, and a top Si layer of 100 µm. The process is schematically represented at (Fig. 3Ca2–h2). The only difference between fabrication using conventional and SiO2 substrates was the upfront definition of the chamber depth of the SOI substrate, dictated by the top Si layer thickness, while for the conventional substrate the depth was determined by the etching time of the second DRIE. Also, the DRIE of the access holes of the SOI wafer is more complex, as the etching using the conventional Bosch process had to be interrupted once the buried SiO2 layer was reached to change into SiO2 etching; once through, we continued with the Bosch process to finish etching the Si (Fig. 3D).

Taxol stabilized microtubules were prepared as described previously35. We used 5 μL of a porcine brain tubulin mixture, having 4 mg mL−1 with 80% unlabeled and 20% fluorescently labeled by Atto647 (Cytoskeleton, Inc.; Denver, CO, USA), incubated with 1.25 μL of polymerization mix having 25% DMSO in 20 mM MgCl2 and 5 mM GTP in BRB80, at 37 °C for 30 min. Subsequently, = 100 μL of BRB80 supplemented with 10 μM Taxol (BRB80T) was added to the polymerized microtubules before centrifugation for 30 min at 18,000 g. Pellets containing microtubules were resuspended in 100 μL of BRB80T and stored at room temperature.

Silanized flow cells were incubated for 5 min with 20 μg·mL-1 anti-tubulin antibody (Sigma Aldrich, T7816, St. Louis, Missouri, USA) and subsequently blocked by 1% pluronic F127 in phosphate-buffered saline (commonly known as PBS for 1 h. Flow cells were then washed with BRB80T and incubated with microtubules for 2 min. Unbound microtubules were removed by BRB80T that were subsequently exchanged for a motility buffer. This buffer (BRB80) contained Taxol with a concentration of 10 µM, dithiothreitol with a concentration of 10 mM, D-glucose with 20 mM, 0.1% Tween-20, 0.5 mg mL−1 casein, 1 mM Mg-ATP, 0.22 mg mL−1 glucose oxidase, and 20 µg mL−1 catalase. For single-molecule stepping, we added to the flow cell 2.5 nM of constitutively active kinesin-1-eGFP into a motility buffer.

The total internal reflection (TIRF) imaging was conducted using an inverted Nikon Eclipse Ti-E wide-field microscope equipped with a 100 × HP APO TIRF objective lens, H-TIRF module, LU-NV Laser Unit (all, Nikon, Tokyo, Japan) and a set of images creating a movie was captured by an sCMOS camera, model ORCA 4.0 V2 (Hamamatsu Photonics, Hamamatsu City, Japan). Movies were acquired for 30 s with 200 ms exposure time using NIS-Elements Advanced Research software v5.21 (Laboratory Imaging, Prague, Czech Republic). In the first frame of the series of captured images forming the movie, both HiLyte647-labelled microtubules and Kinesin-1-eGFP were imaged by sequential laser excitation via quad-band set filter model TRF89901v2 (Chroma Technology Corp., Bellows Falls, VT, USA). The remaining frames of the movie were acquired only for Kinesin-1-eGFP fluorescence to increase the frame rate of the captured movies. Signal to noise ratio of the acquired images was quantified using ImageJ software (NIST, Gaithersburg, MA, USA)36.

We placed both chips under an optical microscope and captured dark field images of both Si chip, the one made of conventional Si (Fig. 4A1) and the second one made of an SOI substrate (Fig. 4A2). We did observe strong light scattering signal from the bottom of the chamber made a conventional Si substrate, while there was practically no scattering observed from the SOI-based chamber; it is this scattering that causes problems with the fluorescent background. We measured the surface topography using a white light optical profiler based on a Mireau interferometer37 equipped with a 50 × objective lens, using vertical shift interferometry mode (VSI) (Fig. 4B1,B2). The roughness of the bulk Si chip surface was 84 × greater than the SOI’s. We also used a stylus type profiler, determining the surface roughness as (76.883 ± 2.068) and (1.863 ± 0.015) nm RMS, both (mean ± standard deviation) for the standard and SOI-based chips, respectively.

(A) Image of the conventional Si surface after etching using dark field microscopy with a 20 × objective lens. (B) Interference image of SOI (top) and standard Si (bottom) wafer chips using VSI mode. The images were processed using the auto-scale mode, with the SOI having a total scale of = 24 nm, while the conventional Si chip has a total scale = of 2.01 µm—thus = 84 × greater. (C) PMT voltage as a function of fluorescein concentration with the type of chamber material as a parameter using logarithmic scales for both axes; red is conventional Si substrate and black is SOI-based substrate.

We then performed fluorescence measurement using an optical microscope equipped with an FITC filter having modulated LED with 475 nm of principal wavelength as illumination, using 10 mA of electrical current modulated at a frequency set to 1.028 kHz. The excited signal was captured by a PMT, with its gain set by the external power supply to 0.5 V, the PMT output processed by a lock-in amplifier with its sensitivity set to 1 V scale−1, time constant to 100 ms, and amplitude recorded by an oscilloscope.

We filled the chambers in the chips with fluorescein with solution, with the dilution starting from = 1 nM up to = 100 µM, while keeping one chamber empty for reference to determine the fluorescence LOD of each chip. Then we measured the fluorescence amplitude from all chambers and plotted it as a function of fluorescein concentration (Fig. 4C). Based on the measurement, the fluorescence LOD of the chip made of a conventional Si substrate is ≈5 times higher.

We tested single-molecule detection in these chips using an established assay38, where microtubules are specifically attached to a surface and the motility of single fluorescently labeled kinesin-1 molecular motors along these microtubules is visualized using TIRF microscopy. A single kinesin-1 motor is a homodimer yielding a relatively low fluorescent signal originating from two attached molecules of green fluorescent protein (GFP). After attaching the microtubules to the chips, we added kinesin-1-GFP at = 2.5 nM concentration, imaged both the microtubules and the kinesin-1, and compared conventional substrate and SOI-based chip compatibility with the assay. Microtubules could be visualized in both chip versions using excitation with light of 640 nm wavelength (Fig. 5). However, the motility of a single GFP-labeled kinesin-1 requiring illumination with 488 nm wavelength could only be successfully visualized using SOI-based chips (Fig. 5 right). This is due to the low level of the signal of single kinesin-1 molecules and the elevated background noise level in the conventional chips (Table 1). The results confirm the suppression of background noise in SOI-based chips and show the capability to use the SOI-based chips for single-molecule detection assays using TIRF microscopy.

TIRF results from the (left) chip made from the conventional substrate and (right) an improvement once the SOI-based chip was used. Microtubule is detectable in both chips. Single kinesin-1-GFP molecules (in micrograph and kymograph indicated by orange and green arrowheads, respectively) can be detected only in the SOI-based chips.

The most significant parameter improvement is an increase of a (mean signal − mean noise)/σ noise ratio by = 17.6 × allowing the determination of motility of a single GFP-labeled kinesin-1 requiring illumination of 488 nm wavelength.

In this contribution, we analyzed the properties of high-end optical filters concerning single-molecule imaging using microfluidics chips.

We would like to stress that the last fabrication step before the anodic bonding closing the microfluidic system was the Si thermal oxidation to grow a SiO2 layer with thickness of 5 nm conducted at 900 °C in dry O2 ambient to define the chamber surface properties. This step in that environment removes all traces of chemicals possibly bonded to the original Si surface. Si as well as the glass used for anodic bonding both do not exhibit any autofluorescence and the only difference between the two different microfluidic chip (Si and SOI-based) is the bottom topography. The rest is identical. Thus whatever the effect is, the bottom line is that it is related to the surface topography and removal of this topography significantly improves the fluorescent measurement (imaging) properties.

We have found that high-resolution imaging, such as was used for single-molecule motility determination using the TIRF technique, does not achieve expected result while using microfluidics chips made by the conventional technique using a bulk silicon substrate, due to possible various effects related to the rough bottom of the structure. We studied this effect and demonstrated the solution that replacing the conventional Si substrate with an SOI substrate guarantees a flat bottom of the microfluidic chip, allowing the TIRF technique to maximize its potential by determining single-molecule motility using illumination at a 488 nm wavelength. Fairly expensive SOI substrates can probably be replaced with conventional Si wafers and allow microfluidic chamber etching through a suitable smoothening technique such as the one based on HF/HNO3 etching39. Regardless, the cost of the original substrate is typically rather marginal in comparison with chip fabrication and especially with its subsequent utilization including single-molecule testing, which justifies this high substrate cost.

There is no data availability section present on system and data can be obtain based on a reasonable request.

Bard, A. J. et al. Electrochemical Methods: Fundamentals and Applications (Wiley, 2022).

Lisdat, F. et al. The use of electrochemical impedance spectroscopy for biosensing. Anal. Bioanal. Chem. 391, 1555–1567 (2008).

Article  CAS  PubMed  Google Scholar 

Bogomolova, A. et al. Challenges of electrochemical impedance spectroscopy in protein biosensing. Anal. Chem. 81, 3944–3949 (2009).

Article  CAS  PubMed  Google Scholar 

Park, J. et al. Direct coupling of a free-flow isotachophoresis (FFITP) device with electrospray ionization mass spectrometry (ESI-MS). Lab Chip 15, 3495–3502 (2015).

Article  CAS  PubMed  Google Scholar 

Länge, K. et al. Analytical and bioanalytical chemistry. Anal. Bioanal. Chem. 391, 1509–1519 (2008).

Rickert, J. et al. Quartz crystal microbalances for quantitative biosensing and characterizing protein multilayers. Biosens. Bioelectron. 12, 567–575 (1997).

Article  CAS  PubMed  Google Scholar 

Song, Y. et al. Colorimetric biosensing using smart materials. Adv. Mater. 23, 4215–4236 (2011).

Article  CAS  PubMed  Google Scholar 

Dutta, S. Point of care sensing and biosensing using ambient light sensor of smartphone: Critical review. TrAC - Trends Anal. Chem. 110, 393–400 (2019).

Piliarik, M. et al. Biosensors and Biodetection 65–88 (Humana Press, 2009).

Mejía-Salazar, J. et al.Plasmonic biosensing: Focus review.Chem. Rev. 118, 10617–10625 (2018).

Neuzil, P. et al. Palm-sized biodetection system based on localized surface plasmon resonance. Anal. Chem. 80, 6100–6103 (2008).

Article  CAS  PubMed  Google Scholar 

Fang, C. et al. Progress of the electrochemiluminescence biosensing strategy for clinical diagnosis with luminol as the sensing probe. ChemElectroChem 4, 1587–1593 (2017).

Wang, H. et al. Recent progress in strategies for the creation of protein-based fluorescent biosensors. ChemBioChem 10, 2560–2577 (2009).

Article  CAS  PubMed  Google Scholar 

Podešva, P. et al. Single nanostructured gold amalgam microelectrode electrochemiluminescence: From arrays to a single point. Sens. Actuators B Chem. 286, 282–288 (2019).

Jusková, P. et al. Detection of electrochemiluminescence from floating metal platelets in suspension. Lab Chip 13, 781–784 (2013).

Martin, M. M. et al. The pH dependence of fluorescein fluorescence. J. Lumin. 10, 381–390 (1975).

Zehentbauer, F. M. et al. Fluorescence spectroscopy of Rhodamine 6G: Concentration and solvent effects. Spectrochim. Acta A 121, 147–151 (2014).

Article  ADS  CAS  Google Scholar 

Valasek, M. A. et al. The power of real-time PCR. Adv. Physiol. Educ. 29, 151–159 (2005).

Vogelstein, B. et al. Digital pcr. Proc. Natl. Acad. Sci. U.S.A. 96, 9236–9241 (1999).

Article  ADS  CAS  PubMed  PubMed Central  Google Scholar 

Song, Y. et al. Recent progress in microfluidics-based biosensing. Anal. Chem. 91, 388–404 (2018).

Wiedenmann, J. et al. Fluorescent proteins for live cell imaging: Opportunities, limitations, and challenges. IUBMB Life 61, 1029–1042 (2009).

Article  CAS  PubMed  Google Scholar 

Nienhaus, K. & Ulrich, N. G. Fluorescent proteins for live-cell imaging with super-resolution. Chem. Rev. 43, 1088–1106 (2014).

Semrock, https://www.semrock.com/FilterDetails.aspx?id=FF02-472/30-25 (2022).

Madic, J. et al. Three-color crystal digital PCR. Biomol. Detect. Quantif 10, 34–46 (2016).

Article  CAS  PubMed  PubMed Central  Google Scholar 

Chroma, I. 49002 - ET - EGFP (FITC/Cy2), https://www.chroma.com/products/sets/49002-et-egfp-fitc-cy2 (2022).

Hardee, C. et al. Interference Filters for Fluorescence Microscopy, https://www.olympus-lifescience.com.cn/en/microscope-resource/primer/techniques/fluorescence/interferencefilterintro/ (2022).

Kuhn, W. K. et al. Effects of surface roughness on surface analysis via soft and ultrasoft X-ray fluorescence spectroscopy. Appl. Surf. Sci. 185, 84–91 (2001).

Article  ADS  CAS  Google Scholar 

Tsuji, K. et al. The effects of surface roughness on the angle‐dependent total‐reflection x‐ray fluorescence of ultrathin films. J. Appl. Phys. 78, 969–973 (1995).

Article  ADS  CAS  Google Scholar 

Goossens, T. et al. Thin-film interference filters illuminated by tilted apertures. Appl. Opt. 59, A112–A122 (2020).

Balram, K. C. et al. J. Res. Natl. Inst. Stand. Technol. 464–476, (2016).

Zhang, H. et al. Nanolithography toolbox—Simplifying the design complexity of microfluidic chips. J. Vac. Sci. Technol. B 38, 063002 (2020).

Zhu, H. et al. Continuous microfluidic mixing and the highly controlled nanoparticle synthesis using direct current-induced thermal buoyancy convection. Microfluid. Nanofluidics 24, 1–8 (2020).

Laerme, F. et al. in Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No. 99CH36291). 211–216 (IEEE).

Castro, E. R. et al. Determination of dynamic contact angles within microfluidic devices. Microfluid. Nanofluidics 22, 1–11 (2018).

Henrichs, V. et al. Mitochondria-adaptor TRAK1 promotes kinesin-1 driven transport in crowded environments. Nat. Commun. 11, 1–13 (2020).

Lima, R. T. et al. Modulation of autophagy by a thioxanthone decreases the viability of melanoma cells. Molecules 21, 1343 (2016).

Article  PubMed Central  Google Scholar 

Wang, Y. et al. Review of surface profile measurement techniques based on optical interferometry. Opt. Lasers Eng. 93, 164–170 (2017).

Gell, C. et al. Microtubule dynamics reconstituted in vitro and imaged by single-molecule fluorescence microscopy. Methods Cell Biol. 95, 221–245 (2010).

Article  CAS  PubMed  Google Scholar 

Bauhuber, M. et al. Isotropic wet chemical etching of deep channels with optical surface quality in silicon with HNA based etching solutions. Mater. Sci. Semicond. Process. 16, 1428–1433 (2013).

We acknowledge the financial support of 52150710541 from NSFC and support of the 2018YFE0109000 project by MOST, both from P.R. China, as well as support from cleanroom staff at the Department of Microsystem Engineering of Northwestern Polytechnical University, Xi’an, P.R. China for the device. We also acknowledge the support of the Charles University Grant Agency (GAUK no. 276321 to J.S.) and the Imaging Methods Core Facility at BIOCEV, an institution supported by the MEYS CR (Large RI Project LM2018129 Czech-BioImaging) and ERDF (Project No. CZ.02.1.01/0.0/0.0/18_046/0016045) for their support with obtaining imaging data presented in this paper.

Department of Microsystems Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi’an, 710072, Shaanxi, People’s Republic of China

Xiaocheng Liu, Hanliang Zhu & Pavel Neužil

Institute of Biotechnology, Czech Academy of Science, Průmyslova 595, 252 50, Vestec, Czech Republic

Ján Sabó & Zdeněk Lánský

Department of Physical Chemistry, Faculty of Science, Charles University, Hlavova 8, 12800, Prague 2, Czech Republic

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

X.L did device fabrication and partial testing H.Z. did optical testing J.S. did cell imaging Z.L. did also cell imaging nad results' interpretation P.N. did the chip design and work conceptualization, he was involved in the testing All co-authors participated in manuscript writing and editing.

Correspondence to Pavel Neužil.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Liu, X., Zhu, H., Sabó, J. et al. Improvement of the signal to noise ratio for fluorescent imaging in microfluidic chips. Sci Rep 12, 18911 (2022). https://doi.org/10.1038/s41598-022-23426-z

DOI: https://doi.org/10.1038/s41598-022-23426-z

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Scientific Reports (Sci Rep) ISSN 2045-2322 (online)

Improvement of the signal to noise ratio for fluorescent imaging in microfluidic chips | Scientific Reports

A Light Microscope Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.